Central Alarm Monitoring Software
Central Alarm Monitoring System, in short “CAMS” are specially design for IP based Disabled Toilet Alarm System for disabled people (people with special needs). CAMS offers monitor all real-time events as they occur in the system which is full networked based running under TCP/IP protocols. In a single subnetwork it supports 244 IP based toilet alarm virtually unlimited system in unlimited distance which is full Client-Server architecture with SQL Database gives backup options thus system never crashes.
Unique solutions that designed only by “XTEC” with Hardware and Software that, different from anything else available on the market as known. Cams support Real-time Alarm monitoring system including real-time Alarm notification, power failure, network disconnections, and system faults and so on. Moreover this solutions support SMS notification, E-Mail notification, BACNet alarm push and Real-time Alarm in E-MAP (Floor layout) which operator can directly see where alarm is activated in real-time for large installed premises, like Air ports, Stadium, museum, hotels and so on.
Latest from XTEC
Related items
- Smart Phone Apps
Smart Phone Apps
Unique solutions of Alarm control for Smart Phones, that designed only by “XTEC” till known, for cloud based real-time alarm notification and control system which is directly connected to the main server of the client premises. Our smart-phone apps named as “Xapps” available for both Android and iPhone and can customized as to the client request.
- Stand Alone Disabled Toilet Alarm System
Stand Alone Disabled Toilet Alarm System
Conventional Stand Alone Accessible Toilet Alarm Kit to BS8300
stand alone disabled toilet alarm system sets or Kit includes everything required for ADA/BS8300 clause compliant emergency assistance alarm. Attractively designed and easy to install as system allows a distressed person to raise an alarm in the event of an emergency.
To operate the user pulls the cord of a ceiling pull cord to activate a light and sounder outside the WC and on the system’s call controller. A new “Call Accept” facility allows staff to send an intermittent call acknowledgement signal to the WC to confirm help is on the way.
The NC951 can be wired in to 4 core stranded security cable but can also be used as a single zone emergency assistance alarm in areas such as changing rooms, solariums, interview rooms, reception areas and more.
Kits Contains:
- 1 x NC943B 12V 140mA Call Controller c/w standby battery and relay
- 1 x NC807C Ceiling Pull Cord
- 1 x NC806CS Overdoor Light c/w Sounder
- 1 x NC809DBBT Accessible Toilet Reset Point c/w Sounder
- 1 x Accessible WC Sticker
{tab=Controller}
Single zone call controller 12V 140mA PSU and standby battery.
Capable of indicating standard and emergency calls.
Includes a volume adjustable sounder
link-selectable Call Accept/Reset button.
Power On and Alarm ‘CALLING’ LEDs.
Volt-free relay output for the optional Fire/BMS
Standby battery provides up to 24 hours standby and 15 minutes alarm running time.
- Stainless steel version also available.
{tab=Ceiling Pull Unit}
Can be used to generate a standard call.
Typically wired as a slave to an 800 Series Call Point or Reset.
Supplied with 3m of red nylon pull cord and two red open-sided triangular bangles.
Red confidence LED and diffuser emits a bright red glow over a wide area to reassure
Surface mountable.
{tab=Reset Point}
A remote reset point sounder specifically designed for Disabled people (braille text)
On-board reassurance LED and sounder provide audible and visual indication
Mounts on a standard UK 25mm single gang flush or surface back box.
- Stainless steel version also available.
{tab=Overdoor Light Sounder}
Provides audible and visual indication of 800 Series Alarm calls outside bedrooms
Indicates Standard calls constant tone and Emergency calls pulsing tone
Dual red LEDs and triangular diffuser make it highly visible from a distance.
Mounts on a standard UK 25mm single gang flush or surface back box.
- Stainless steel version also available.
{tab=Downloads} Click to download Datasheet
{tab=Costing} Please call us at +971 04 421 9920 or email at mail @xtec.me
{/tabs}
For more please contact us at any-time. - IP Toilet Alarm System
IP Toilet Alarm System
IP Disabled Toilet Alarm includes everything required for ADA or BS8300 disabled act to compliant emergency assistance alarm. XTEC IP DTA system available plastic and Stainless steel version. This IP DTA design to install for 1-toilets to 250 toilets in a single network/server having options for (i) Real-time monitoring (ii) Alarm Accept (iii) Alarm MAP (iv) SMS (v) alarm pop-up (vi) Full Alarm report (xls) (vii) alarm statistic and many more. Attractively designed and easy to install and almost plug-play system as connect DTA devices, plug-in into Network and start monitoring in Alarm Monitoring software.
To operate the user pulls the cord of a ceiling pull cord or to press call buttons to activate a light and sounder outside the wc and alarm information sent through network to its monitoring server. Operator acknowledge this and and take initiative according to customer requirement. Also all alarm can me exported as required.
{tab= IP Controller}IP controller usually powered by 230vac. Standby batteries are included and there is an integral battery fault monitor. The system voltage is 12vdc thus the ancillary items in toilets or other wet areas are at a safe working voltage avoiding any conflict with Part P building regulations.
- Audible & visual indication
- Mains/12vdc and battery powered versions
- Battery condition monitor
- Pull cord instructions label with braille text
- Reset button with braille text
- Selectable tones
- Built-in Backup battery
{tab= IP Module} IP Module provides TCP/IP or network connection for disabled toilet alarm system through existing IP network for alarm applications. Direct RJ45 connector can be connected to the IP module, which supports 10/100Mbps connection.- Full control using a standard web browser
- Can operate as a Modbus/TCP slave:
- Auto-Reboot controller mode
- Power supply :9-28VDC{tab=Ceiling Pull Unit} Ceiling Pull unit with LED incorporates a current limit resistor for use on 12vdc. Please remember that for nurse call pulls, to comply with legislation you must have 1 bangle 100mm from the floor and another bangle 800mm - 1000mm from the floor.
{tab=Reset}Wall mounting Press to Reset button with Braille text plus 2 yellow LEDs and sounder for caller reassurance. Enclosed in white ABS plastic, complete with a single gang surface mounting box. Flush fitting is also possible with a standard single gang back box.
- Mark resistant decal
- Tactile button
- Two high brightness yellow LEDs
- Integral sounder
- Back box for surface mount
- Flush mount onto 18mm standard box{tab=O/D Strobe}Overdoor light and sounder with high brightness LEDs. The LEDs and sounder are current limited for 12vdc operation. There are separate inputs for sounder and LEDs. The single gang low profile white ABS enclosure is supplied with a surface mounting back box.
- Mark resistant decal
- Eight high brightness yellow LEDs
- Integral sounder
- Back box for surface mount
- Flush mount onto 18mm standard box{tab=IP Software} Please contact us directly for more details for customization.
{tab=Downloads}Click to download Datasheet
{tab=Costing} Please call us at +971 04 421 9920 or email at mail (a) xtec.me - Disabled toilet alarm kits
Disabled Toilet Alarm kits
Disabled toilet alarm kits, Conventional Accessible Toilet Alarm Kit to BS8300. Disabled toilet alarm includes everything required for ADA/BS8300 clause compliant emergency assistance alarm. Attractively designed and easy to install the NC951 allows a distressed person to raise an alarm in the event of an emergency.
To operate the user pulls the cord of a ceiling pull cord to activate a light and sounder outside the WC and on the system’s call controller. A new “Call Accept” facility allows staff to send an intermittent call acknowledgement signal to the WC to confirm help is on the way.
The NC951 can be wired in to 4 core stranded security cable but can also be used as a single zone emergency assistance alarm in areas such as changing rooms, solariums, interview rooms, reception areas and more.
Kits Contains:
- 1 x NC943B 12V 140mA Call Controller c/w standby battery and relay
- 1 x NC807C Ceiling Pull Cord
- 1 x NC806CS Overdoor Light c/w Sounder
- 1 x NC809DBBT Accessible Toilet Reset Point c/w Sounder
- 1 x Accessible WC Sticker
{tab=Controller}
Single zone call controller 12V 140mA PSU and standby battery.
Capable of indicating standard and emergency calls.
Includes a volume adjustable sounder
link-selectable Call Accept/Reset button.
Power On and Alarm ‘CALLING’ LEDs.
Volt-free relay output for the optional Fire/BMS
Standby battery provides up to 24 hours standby and 15 minutes alarm running time.
- Stainless steel version also available.
{tab=Ceiling Pull Unit}
Can be used to generate a standard call.
Typically wired as a slave to an 800 Series Call Point or Reset.
Supplied with 3m of red nylon pull cord and two red open-sided triangular bangles.
Red confidence LED and diffuser emits a bright red glow over a wide area to reassure
Surface mountable.
{tab=Reset Point}
A remote reset point sounder specifically designed for Disabled people (braille text)
On-board reassurance LED and sounder provide audible and visual indication
Mounts on a standard UK 25mm single gang flush or surface back box.
- Stainless steel version also available.
{tab=Overdoor Light Sounder}
Provides audible and visual indication of 800 Series Alarm calls outside bedrooms
Indicates Standard calls constant tone and Emergency calls pulsing tone
Dual red LEDs and triangular diffuser make it highly visible from a distance.
Mounts on a standard UK 25mm single gang flush or surface back box.
- Stainless steel version also available.
{tab=Downloads} Click to download Datasheet
{tab=Costing} Please call us at +971 04 421 9920 or email at mail (a) xtec.me
For more please contact us at any-timeContact us for More Info
{loadformmaker 18} - IP Disabled Toilet Alarm
IP Disabled Toilet Alarm
IP Disabled Toilet Alarm includes everything required for ADA or BS8300 disabled act to compliant emergency assistance alarm. XTEC IP DTA system available plastic and Stainless steel version. This IP DTA design to install for 1-toilets to 250 toilets in a single network/server having options for (i) Real-time monitoring (ii) Alarm Accept (iii) Alarm MAP (iv) SMS (v) alarm pop-up (vi) Full Alarm report (xls) (vii) alarm statistic and many more. Attractively designed and easy to install and almost plug-play system as connect DTA devices, plug-in into Network and start monitoring in Alarm Monitoring software.
To operate the user pulls the cord of a ceiling pull cord or to press call buttons to activate a light and sounder outside the wc and alarm information sent through network to its monitoring server. Operator acknowledge this and and take initiative according to customer requirement. Also all alarm can me exported as required.
{tab= IP Controller}IP controller usually powered by 230vac. Standby batteries are included and there is an integral battery fault monitor. The system voltage is 12vdc thus the ancillary items in toilets or other wet areas are at a safe working voltage avoiding any conflict with Part P building regulations.
- Audible & visual indication
- Mains/12vdc and battery powered versions
- Battery condition monitor
- Pull cord instructions label with braille text
- Reset button with braille text
- Selectable tones
- Built-in Backup battery
{tab= IP Module} IP Module provides TCP/IP or network connection for disabled toilet alarm system through existing IP network for alarm applications. Direct RJ45 connector can be connected to the IP module, which supports 10/100Mbps connection.- Full control using a standard web browser
- Can operate as a Modbus/TCP slave:
- Auto-Reboot controller mode
- Power supply :9-28VDC{tab=Ceiling Pull Unit} Ceiling Pull unit with LED incorporates a current limit resistor for use on 12vdc. Please remember that for nurse call pulls, to comply with legislation you must have 1 bangle 100mm from the floor and another bangle 800mm - 1000mm from the floor.
{tab=Reset}Wall mounting Press to Reset button with Braille text plus 2 yellow LEDs and sounder for caller reassurance. Enclosed in white ABS plastic, complete with a single gang surface mounting box. Flush fitting is also possible with a standard single gang back box.
- Mark resistant decal
- Tactile button
- Two high brightness yellow LEDs
- Integral sounder
- Back box for surface mount
- Flush mount onto 18mm standard box{tab=O/D Strobe}Overdoor light and sounder with high brightness LEDs. The LEDs and sounder are current limited for 12vdc operation. There are separate inputs for sounder and LEDs. The single gang low profile white ABS enclosure is supplied with a surface mounting back box.
- Mark resistant decal
- Eight high brightness yellow LEDs
- Integral sounder
- Back box for surface mount
- Flush mount onto 18mm standard box{tab=IP Software} Please contact us directly for more details for customization.
{tab=Downloads}Click to download Datasheet
{tab=Costing} Please call us at +971 04 421 9920 or email at mail (a) xtec.me - IP Disabled Alarm
Our IP disabled toilet alarm system can be expanded over large areas using network and internet infrastructure. Individual toilets can be added to the main toilet alarm system. Stand-alone toilet alarm systems with local control and monitoring can be integrated into a centralised system. Interfaces for integration with BMS and other third party systems available. Ideal for large buildings or multi-site establishments with centralised or off-site facilities management / monitoring., and has applications in hospitals, elderly homes, schools, factories, restaurants, hotels, and any other facility with a risk of injury in private areas. {tab= Details}
Being IP, it is much easier and quicker to install in existing network, and therefore less labor intensive and more economic. It has applications in all kinds of public and commercial buildings, including hospitals, elderly homes, schools, universities, factories, offices, restaurants, hotels, shops, etc. The alarm is distinctive in appearance and sound, so it cannot be confused with fire alarms, and is specifically for the disabled person to gain help in an emergency.{tab=Features}
- Basic system includes a waterproof call button with pull cord
- Waterproof reset button to cancel the alarm after rescue
- Emergency call alarm located outside the room
- Buttons waterproof to IP 65 with pull cord
- Can be monitored centrally from a security desk
- Compatible with wireless repeater to cover long distance
{tab=Specifications}
Add individual toilet alarms over network
Add local toilet alarm systems over network
Local, centralized, off-site monitoring / event logs available
Makes use of existing infrastructure
Reduces cabling costs, allows retro-fitting etc.
Ideal for large buildings, campuses etc.{tab=Architecture}
{tab=Download}Download Datasheet for IP DTAS
{tab=Software}
{tab=Inquiry} mail (a) xtec.me
- Disabled toilet alarm kits
Disabled toilet alarm kits, Conventional Accessible Toilet Alarm Kit to BS8300
Disabled toilet alarm includes everything required for ADA/BS8300 clause compliant emergency assistance alarm. Attractively designed and easy to install the NC951 allows a distressed person to raise an alarm in the event of an emergency.
To operate the user pulls the cord of a ceiling pull cord to activate a light and sounder outside the WC and on the system’s call controller. A new “Call Accept” facility allows staff to send an intermittent call acknowledgement signal to the WC to confirm help is on the way.
The NC951 can be wired in to 4 core stranded security cable but can also be used as a single zone emergency assistance alarm in areas such as changing rooms, solariums, interview rooms, reception areas and more.
Kits Contains:
- 1 x NC943B 12V 140mA Call Controller c/w standby battery and relay
- 1 x NC807C Ceiling Pull Cord
- 1 x NC806CS Overdoor Light c/w Sounder
- 1 x NC809DBBT Accessible Toilet Reset Point c/w Sounder
- 1 x Accessible WC Sticker
{tab=Controller}
Single zone call controller 12V 140mA PSU and standby battery.
Capable of indicating standard and emergency calls.
Includes a volume adjustable sounder
link-selectable Call Accept/Reset button.
Power On and Alarm ‘CALLING’ LEDs.
Volt-free relay output for the optional Fire/BMS
Standby battery provides up to 24 hours standby and 15 minutes alarm running time.
- Stainless steel version also available.
{tab=Ceiling Pull Unit}
Can be used to generate a standard call.
Typically wired as a slave to an 800 Series Call Point or Reset.
Supplied with 3m of red nylon pull cord and two red open-sided triangular bangles.
Red confidence LED and diffuser emits a bright red glow over a wide area to reassure
Surface mountable.
{tab=Reset Point}
A remote reset point sounder specifically designed for Disabled people (braille text)
On-board reassurance LED and sounder provide audible and visual indication
Mounts on a standard UK 25mm single gang flush or surface back box.
- Stainless steel version also available.
{tab=Overdoor Light Sounder}
Provides audible and visual indication of 800 Series Alarm calls outside bedrooms
Indicates Standard calls constant tone and Emergency calls pulsing tone
Dual red LEDs and triangular diffuser make it highly visible from a distance.
Mounts on a standard UK 25mm single gang flush or surface back box.
- Stainless steel version also available.
{tab=Downloads} Click to download Datasheet
{tab=Costing} Please call us at +971 04 421 9920 or email at mail (a) xtec.me
{/tabs}
For more please contact us at any-time. - Networked Panic Alarm
Networked Panic Alarm
A Networked Panic Alarm (NPA) usually consists of buttons which, when pressed, activates the alarm by sending a signal to either the local emergency controller or over IP networks, to take an action to assist someone who is in trouble, or to a monitoring service. The advantages of NPA is allowing to take advantage of existing network cabling when upgrading systems or adding new devices to existing equipment without any extra cost or cabling. NPA system supports 1 nos to 254 panic alarm in a single networks up-to 4096 in a server.
{tab=Details}
Being IP, it is much easier and quicker to install in existing network, and therefore less labor intensive and more economic. Montoring centrallay with all events and records all alarms. It has applications in all kinds of public and commercial buildings, including hospitals, elderly homes, schools, universities, factories, offices, restaurants, hotels, shops, etc. The alarm is distinctive in appearance and sound, so it cannot be confused with fire alarms, and is specifically for the disabled person to gain help in an emergency.
{tab=Features}- Push to call buttons with manual key
- Basic system includes a waterproof call button
- Waterproof reset button to cancel the alarm after rescue
- Emergency call alarm located outside the room
- Buttons waterproof to IP 65 with pull cord
- IP69 waterproof can be use in spa, suana
- Can be monitored centrally from a security desk
- Compatible with wireless repeater to cover long distance
{tab=Specifications}- Add individual alarms over network
- Add local alarm systems over network
- Local, centralized, off-site monitoring / event logs available
- Makes use of existing infrastructure
- Reduces cabling costs, allows retro-fitting etc.
- Ideal for large buildings, campuses etc.
{tab=Architecture}
{tab=Download}Download Datasheet for Networked Panic Alarm
{tab=Inquiry} mail (a) xtec.me{loadformmaker 18}
- Stand Alone Disabled Toilet Alarm in Products
Conventional Stand Alone Accessible Toilet Alarm Kit to BS8300
stand alone disabled toilet alarm system sets or Kit includes everything required for ADA/BS8300 clause compliant emergency assistance alarm. Attractively designed and easy to install as system allows a distressed person to raise an alarm in the event of an emergency.
To operate the user pulls the cord of a ceiling pull cord to activate a light and sounder outside the WC and on the system’s call controller. A new “Call Accept” facility allows staff to send an intermittent call acknowledgement signal to the WC to confirm help is on the way.
The NC951 can be wired in to 4 core stranded security cable but can also be used as a single zone emergency assistance alarm in areas such as changing rooms, solariums, interview rooms, reception areas and more.
Kits Contains:
- 1 x NC943B 12V 140mA Call Controller c/w standby battery and relay
- 1 x NC807C Ceiling Pull Cord
- 1 x NC806CS Overdoor Light c/w Sounder
- 1 x NC809DBBT Accessible Toilet Reset Point c/w Sounder
- 1 x Accessible WC Sticker
{tab=Controller}
Single zone call controller 12V 140mA PSU and standby battery.
Capable of indicating standard and emergency calls.
Includes a volume adjustable sounder
link-selectable Call Accept/Reset button.
Power On and Alarm ‘CALLING’ LEDs.
Volt-free relay output for the optional Fire/BMS
Standby battery provides up to 24 hours standby and 15 minutes alarm running time.
- Stainless steel version also available.
{tab=Ceiling Pull Unit}
Can be used to generate a standard call.
Typically wired as a slave to an 800 Series Call Point or Reset.
Supplied with 3m of red nylon pull cord and two red open-sided triangular bangles.
Red confidence LED and diffuser emits a bright red glow over a wide area to reassure
Surface mountable.
{tab=Reset Point}
A remote reset point sounder specifically designed for Disabled people (braille text)
On-board reassurance LED and sounder provide audible and visual indication
Mounts on a standard UK 25mm single gang flush or surface back box.
- Stainless steel version also available.
{tab=Overdoor Light Sounder}
Provides audible and visual indication of 800 Series Alarm calls outside bedrooms
Indicates Standard calls constant tone and Emergency calls pulsing tone
Dual red LEDs and triangular diffuser make it highly visible from a distance.
Mounts on a standard UK 25mm single gang flush or surface back box.
- Stainless steel version also available.
{tab=Downloads} Click to download Datasheet
{tab=Costing} Please call us at +971 04 421 9920 or email at mail @xtec.me
{/tabs}
For more please contact us at any-time. - Disabled Toilet Alarm
Disabled Toilet Alarm Disabled Toilet Alarm , This Disabled Persons Toilet Alarm is available as a single zone kit to allows a distressed person to raise an alarm in the event of an emergency. To operate, the user simply press a button or pulls the cord of a ceiling pull unit to activate a light and sounder outside the WC. Disabled Toilet Alarm can be use for central monitoring. Battery backup plus alarm running time in the even of mains failure. Available in both plastic and brushed stainless steel to suit any application from single zone to multi-zone, Conventional, Addressable and IP versions with Software monitoring.Attractively designed, easy to install and simple to use.
Stand-Alone Disabled Toilet Alarm Disabled Toilet Alarm, Our complete disabled toilet alarm kits provide everything you need to install a fully-functional disabled toilet alarm. Standards Disabled Toilet Alarm is designed to meet the latest requirements and various other care standards. It is a very simple system to install and expand.
Vandal resistant Steel, BS compliant, disabled toilet emergency assistance alarm systems for public use. The pull cord, coloured red for high-visibility, has two rings that should be positioned in specific locations – one should be only 100mm from the floor and the other should be at a height of 800-1000mm, reachable from the WC. The reset button, which has a sounder to indicate to the disabled person that assistance is on the way.
Centralized Disabled Toilet Alarm Disabled Toilet Alarms, We can ensure the safety of disabled toilet users with our comprehensive range of disabled toilet alarms. Centralized Disabled Toilet Alarm is designed on latest technilogy to meet Multiple Alarm Monitoring with height standard and various other care standards. It can be single system for single toilets or site-wide systems with multiple monitoring stations, central control stations, BMS interfaces etc. Individual alarms can be grouped and monitored locally and/or from a central monitoring stations. All systems are battery backed for peace of mind during power outages.
Addressable Disabled Toilet Alarm Disabled Toilet Alarm, Our range of BS8300 disabled toilet alarm systems includes a selection of waterproof products. Addressable System (ADTAS) that helps ensures help assistance centrally in any environments emergency assistance, including alarm call points, displays, ceiling pulls, Overdoor lights with strobe, LCD display for alarm, can be upgrade to central monitoring software through RS485 network to security or monitoring room. A single system support up-to 250 toilets which having built-in power backup for 48 hours nd 5 programmable BMS/Fire interface.
IP Disabled Toilet Alarm IP disabled toilet alarm system can be expanded over large areas using network infrastructure. Our any Individual toilets can be added to the central DTA alarm monitoring system. Stand-alone toilet alarm systems with local control and monitoring can be integrated into a centralized system. Interfaces for integration with BMS and other third party systems available. Ideal for large buildings or multi-site establishments with centralized or off-site facilities management / monitoring., and has applications in hospitals, elderly homes, schools, factories, restaurants, hotels, and any other facility with where centrally monitoring requires.
Wireless Disabled Toilet Alarm Wireless disabled call system will send an alert to gain immediate help in an emergency, and is designed to meet the worldwide need and desire to better serve disabled people. It complies with regulations devised to ensure barrier free entry and use of public facilities by the disabled, and has applications in hospitals, elderly homes, schools, factories, restaurants, hotels, and any other facility with a risk of injury in private areas.
Contact us for more information
{loadformmaker 18}